    • 产品名称: Micro ACP 300
    • 产品编号: 柔性AC迷你电流传感器 ACP 300
    • 产品概况 Micro ACP 300The new Micro~flex ACP 300 is an AC current Probe utilisingthe Rogowski principle. It can be used to measure currentsup to 300 Amps from very low frequencies to 70kHz.The flexible and lightweight measuring head allows quickand easy installation in hard to reach areas and with largeconductors.?

    Micro ACP 300

    The new Micro~flex ACP 300 is an AC current Probe utilising

    the Rogowski principle. It can be used to measure currents

    up to 300 Amps from very low frequencies to 70kHz.

    The flexible and lightweight measuring head allows quick

    and easy installation in hard to reach areas and with large

    conductors.

     

    Micro ACP 300

    Electrical Characteristics

    Current Ranges (selectable via rotary switch).......... : 3A / 30A / 300A ACRMS

    Output Sensitivity (AC coupled) ............................... : 500mV / 50mV / 5mV per A

    Accuracy (at 25°C) ................................. ................. : ± 1% of reading ± 0.1A (3A)

    ………………………………………………………….. : ± 1% of reading ± 0.2A (30A)

    ……………………………………………………………: ± 1% of reading ± 0.5A (300A)

    Load Impedance...................................................... : 100k_ minimum

    Linearity (10% to 100% of range) ............................ : ± 0.2% of reading

    Noise....................................................................... : 60mA (3A) / 80mA (30A) / 200mA (300A range)

    Bandwidth (-1dB)..................................................... : 15Hz to 70kHz

    Phase Error (45 – 65Hz).......................................... : ± <1º

    Temperature Coefficient .......................................... : ± 0.1% of reading / °C

    Position Sensitivity .................................................. : ± 2% of reading

    External Field (with cable > 100mm from the head). : ± 0.2% of range

    Power Supply .......................................................... : 2 x AA MN 1500 LR6 Alkaline

    ................................................................................ : 100 hours, low battery indicator

    ……………………………………………………………: external power supply (3V / 100mA)

    Overload Indication ................................................. : Red LED ON indicates the range overload

    Working Voltage (see Safety Standards section)..... : 1000V AC RMS or DC (Probe), 30V max output

    Micro ACP 300

    General Characteristics

    Probe and Cable Material ........................................ : Alcryn 2070 NC LATENE 7H2W V0

    Probe Conductor Diameters …................................ : 50mm / 70mm / 100mm

    Probe Cable Diameter ............................................. : 6mm (nominal)

    Cable Length (Probe to Integrator box) ................... : 2m

    Output ..................................................................... : 0.5m long lead terminated with 4mm safety plugs

    Operating Temperature Range................................ : -20 to +65°C

    Storage Temperature Range................................... : -40 to +75°C

    Operating Humidity …………………………………….: 15% to 85% (non condensing)

    Degree of protection……………………………………: IP50 Probe, IP40 Integrator module